Activate Error: Automation Error The specified module could not be found.

Published: 2015-07-21

 

Last Updated: 2015-07-21

 

Applies To

 

 

Symptoms

If you open the Activation Wizard, this error appears

 

 

 

Cause

The current user does not have sufficient rights to the license activation folder and/or to the registry keys.

 

 

Resolution

Follow these steps to resolve this activation error.

  1. Browse to the folder C:\ProgramData\TimeKeeping Systems\License Activation Wizard.
  2. Delete the DataStore.xml file.
  3. Open the Registry Editor by opening a command line prompt and typing regedit. If you do not have permissions to edit the registry editor, log off and log in with a local administrator account.
  4. Verify that the current windows account has “Full Control” permissions on the Registry Key HKEY_CURRENT_USER\Software\Timekeeping Systems and all of its Sub Keys (LAW) .
  5. Close the Registry Editor.
  6. From the Start button, open All Programs>TimeKeeping Systems>Guard1 Plus> Activation Wizard and right-click to Run as Administrator.
  7. Follow the directions provided to activate your Guard1 Plus installation.

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2013-2016 TimeKeeping Systems, Inc.